Monitoring Temperature and Depth in Stormwater Systems

Monitoring Temperature and Depth in Stormwater Systems

The PTLevel and Stormwater Management

The PTLevel Wired WiFi can now measure depth and temperature, often required in Stormwater Retention and Detention Ponds! The Long Range Wireless version is coming soon.

What is a Stormwater Management System?

A stormwater retention pond, also known as a detention pond or stormwater management pond, is a artificial basin designed to capture and temporarily hold stormwater runoff and often requires depth and temperature monitoring. Stormwater runoff occurs when rainwater or melted snow flows over impervious surfaces. Runoff from roads, parking lots, and rooftops cannot be absorbed into the ground and that water has to go somewhere to prevent flooding.

The primary purpose of a stormwater retention pond is to control the flow of stormwater and reduce the risk of flooding. It achieves this by temporarily storing the excess water and releasing it at a controlled rate. As a result, this allows for gradual discharge into the natural drainage system (eg rivers). The pond also enables sedimentation, allowing suspended particles to settle out before releasing the water.

Typically, designers of stormwater retention ponds incorporate specific features such as an inlet structure to collect runoff, an outlet structure to release controlled flows, and a pond basin that can hold water during storm events. They may also integrate vegetation into the design to help stabilize the banks and improve water quality through natural processes.

Stormwater Management Monitoring Requirements


Many cities, regions, counties, and provinces or states have their own requirements for stormwater monitoring. They require these to demonstrate that the facilities are functioning as designed. Location-specific assessments should determine the scope, approach, frequency, and extent of the monitoring program for stormwater management facility performance. This ensures that the program is not over- or under-scoped (eg. it is the right size for the site). Specifically, depth and temperature monitoring are often part of the stormwater monitoring requirements.

Stormwater Depth Monitoring


In Niagara, Ontario there is a requirement for depth monitoring at the inlet and outlet of the stormwater facility.

Stormwater quantity monitoring to verify stormwater management facility performance shall be completed as required by the Local Municipality and/or Region. Depth probes shall be installed at the inlet and outlet of the stormwater management facility to determine the operating water surface elevations within the facility during storm events. The water surface elevations shall be correlated to storage and discharge rates based upon the stormwater management facility rating curve as determined by the as-built survey of the facility after cleanout and prior to assumption by the Local Municipality or Region.

"Available rainfall data shall be used to determine the corresponding return period of the storm event, for comparison and verification of the operating water levels within the facility. Where required by the Municipality and/or Region, the approved hydrologic models shall be updated to represent the as-built condition of the stormwater management facility and contributing drainage area, and hydrologic analyses completed to verify the stormwater management facility performance."
Stormwater Management Guidelines, Project No. TPB208013, Niagara Region, Page 113

To find out what stormwater monitoring requirements for depth and temperature are required in your area, reach out to your local authority.

Stormwater Quality Monitoring – Temperature

Various factors, including the temperature of the rain, the surface it falls on, and ambient environmental conditions, can influence the temperature of stormwater. Generally, when rainwater falls, it tends to be close to the temperature of the atmosphere it is falling through.

However, the temperature of stormwater can change after it comes into contact with surfaces like roads, parking lots, or buildings. The surfaces can absorb and retain heat, causing the stormwater to increase in temperature.

In our region, stormwater temperature monitoring is sometimes required at the upstream and downstream. The actual requirements are based on pre-consultation with the Region and relevant authorities.

To find out what stormwater monitoring requirements for depth and temperature are required in your area, reach out to your local authority.

The Solution

We’re excited to announce the launch of the PTLevel Water Level Monitor with Temperature Probe. The Wired WiFi PTLevel provides monitoring for water depth and temperature data for stormwater systems, updating to the cloud every 2 minutes. It is an affordable solution made in Ontario, Canada (worldwide shipping available).
Having automatic and instant data collection can:
  1. save manpower hours with water collection methods
  2. prevent safety issues by eliminating unsafe water collection in high/low water periods
  3. supply valuable graphs with level and temperature trends
  4. provide alerts at concerning high or low temperatures and high or low levels

(The Long Range Wireless PTLevel with a temperature probe is coming soon! In addition to the temperature probe, the Long Range Wireless PTLevel has up to 1 km of range)

The temperature probe can be installed into liquid, attached to a pipe, or simply installed to measure ambient temperatures.

The pressure chamber (for depth) and temperature probe can provide stormwater monitoring in clean or dirty liquids. Examples include polluted stormwater systems, turbid environments, or stormwater systems with debris such as garbage or leaves.

Order here for quick shipping (prepped for shipping the same or next day)!
Temperature Sensor


    • Related Articles

    • Water Monitoring in New York: Agriculture, Residential, and Tides

      Water Monitoring in New York: Challenges and Solutions with PTLevel New York is a state of incredible diversity when it comes to water resources. From the iconic reservoirs supplying New York City to private wells in rural upstate areas, the need for ...
    • Graphs and History - Wired WiFi PTLevel

      In June of 2023 we implemented new data graphs with some amazing new features! To access all graphs (and power settings, alert options, etc), log into your ptdevices.com account and click the 3 dots to the right of your tank name: Level Graphs The ...
    • Graphs and History - Wireless

      In June of 2023 we implemented new data graphs with some amazing new features! To access all graphs (and power settings, alert options, etc), log into your ptdevices.com account and click the 3 dots to the right of your tank name: Level Graphs The ...
    • Level Reading Maintenance - Long Range Wireless PTLevel

      Now that you have your PTLevel setup, you’re probably wondering what to do over time in order to maintain the device and it’s readings. There’s really not much to do, but as with everything, a little bit of maintenance goes a long ways. Maintenance ...
    • California, USA - A Diverse Geography and Climate

      Using the PTLevel in California: Reliable Water Monitoring in a Diverse Climate California, the most populous state in the United States, is renowned for its diverse geography and climate. From the sunny beaches of Southern California to the towering ...