Set Up - Wired (Ethernet)
What is the Maximum Depth the PTLevel Wired can Measure?
The Wired PTLevel is shipped with 13' of tubing, however upon request we can supply longer tubing. The device can monitor up to 25' of water and anything deeper than that, we'd need to send you a larger "Pressure Chamber" for it to work properly. ...
How Often Does the PTLevel Wired Report?
The Wired PTLevel updates online every 30 seconds. Because it is powered by the Ethernet cable, it updates often.
Can I use any Ethernet Cables with the PTLevel Wired?
Yes, you can use any Ethernet cable. We recommend that you use a bury rated cable for any exposure to the sun or the ground. Otherwise, anything will work!
Power Over Ethernet (POE) and the PTLevel Wired
We supply a POE adapter and Power supply with every Wired PTLevel sold. This adapter is installed on the router end of the Ethernet cable and powers the PTLevel so that you only have to run one cable that is used for communications and power. You ...
Can the PTLevel Wired be Installed Outside?
Absolutely. All PTLevel devices are designed specifically to handle the outdoor environment. A few tips for outdoor installations: We recommend that you keep the small tubing that is exposed to the outdoors as short as possible. Make sure that the ...
Comfast Repeater Setup
In this article, we will go over how to setup a Comfast Wifi repeater used to wirelessly extend an Ethernet connection. Please note we no longer sell or provide Comfast Repeaters as our Long Range Wireless PTLevel can achieve up to 1km of range! If ...
Installation Instructions for Wired PTLevel (Discontinued)
How to install the Wired PTLevel device. These instructions are provided with the water level monitor that you purchase as well.
Popular Articles
How Often Does the PTLevel Wireless Report Online?
The Wireless PTLevel is designed to be battery conscious and with that, it implements a special monitoring schedule. By default, it wakes up every 30 minutes to check the level. Then, if the level is out by approx. 10% since the last 30 minute check, ...
Level Reading Maintenance - Long Range Wireless PTLevel
Now that you have your PTLevel setup, you’re probably wondering what to do over time in order to maintain the device and it’s readings. There’s really not much to do, but as with everything, a little bit of maintenance goes a long ways. Maintenance ...
Wireless Device Installation Instructions
This article is for downloading the Long Range Wireless PTLevel Instruction Manual. To learn the step-by-step process of installing the device in a cistern, with pictures, visit our PTLevel Cistern Setup Page: ...
WIFI Connection Procedure
LET’S GET YOUR PTLEVEL CONNECTED To top Below are a couple of videos on how to connect your PTLevel receiver to your WiFi at home. You need to do this if you are setting it up for the first time or if you’ve changed your home password or network SSID ...
Calibration Procedure and Sensor Accuracy
After you’ve installed your new device and setup the depth of your tank, you must calibrate the device in order to achieve a proper reading. This process is simple and is explained below. You can not calibrate at 0% or really low levels, and you must ...